# Temp Gopher
|
||||
|
||||
Temp Gopher is a thermostat application written in Go. It is written and tested using a Raspberry Pi, but any hardware platform meeting the requirements will probably work.
|
||||
|
||||
## Requirements
|
||||
|
||||
You will need a computer (e.g., Raspberry Pi) with the following components:
|
||||
|
||||
* A network connection
|
||||
* DS18B120, 1-wire temperature sensors
|
||||
* GPIO pins
|
||||
* Relays for powering on/off your equipment hooked up to the GPIO pins
|
||||
|
||||
## Installation
|
||||
|
||||
You can build on a Raspberry Pi, however, it can take a long time! I recommend building on a separate computer with a bit more processing power.
|
||||
|
||||
```
|
||||
go get gitea.shoup.io/mike/temp-gopher
|
||||
cd $GOPATH/src/gitea.shoup.io/mike/temp-gopher
|
||||
GOOS=linux GOARCH=arm GOARM=6 go build -a -ldflags '-w -s -extldflags "-static"'
|
||||
scp temp-gopher <raspberrypi>:~/somepath
|
||||
```
|
||||
|
||||
## Configuration
|
||||
|
||||
Create a `config.yml` file like this:
|
||||
|
||||
```
|
||||
sensors:
|
||||
- id: 28-000008083108 # Id of the DS18b120 sensor
|
||||
alias: fermenter # An alias for the sensor
|
||||
hightemp: 8 # Maximum temperature you want the sensor to read
|
||||
lowtemp: 4 # Minimum tempearture you want the sensor to read
|
||||
heatgpio: 5 # GPIO pin the heater is hooked into
|
||||
heatinvert: false # Probably false. If true, will set pin to High to turn the heater off
|
||||
heatminutes: 1 # Number of minutes below the minimum before the heater turns on
|
||||
coolgpio: 17 # GPIO pin the cooler is hooked into
|
||||
coolinvert: false # Probably false. If true, will set pin to High to turn the cooler off
|
||||
coolminutes: 10 # Number of minutes below the minimum before the cooler turns on
|
||||
verbose: false # If true, outputs the current status at every read, approx once per second
|
||||
```
|
||||
|
||||
## Running
|
||||
|
||||
You can run it directly in the comment line like:
|
||||
|
||||
```
|
||||
./temp-gopher -c config.yml run
|
||||
```
|
||||
|
||||
You can run it in the background using `nohup`:
|
||||
|
||||
```
|
||||
nohup ./temp-gopher -c config.yml run &
|
||||
```
|
||||
|
||||
Or use `systemctl` or some other process supervisor to run it.
|
||||
|
|
|
|||